实时计算 Flink版操作报错之抽取Oracle11g时,报错: "Retrieve schema history failed, the schema records for engine ... has been removed",怎么处理

本文涉及的产品
实时计算 Flink 版,5000CU*H 3个月
简介: 在使用实时计算Flink版过程中,可能会遇到各种错误,了解这些错误的原因及解决方法对于高效排错至关重要。针对具体问题,查看Flink的日志是关键,它们通常会提供更详细的错误信息和堆栈跟踪,有助于定位问题。此外,Flink社区文档和官方论坛也是寻求帮助的好去处。以下是一些常见的操作报错及其可能的原因与解决策略。

问题一:测试flinkcdc3.0 同步mysql到doris,就是docs里的例子,怎么都不成功?


测试flinkcdc3.0 同步mysql到doris,就是docs里的例子,17kb的源库,怎么都不成功?flink版本1.17.2source: type: mysql hostname: localhost port: 3306 username: root password: 123456 tables: app_db..* server-id: 5400 server-time-zone: UTCsink: type: doris fenodes: 127.0.0.1:8030 username: root password: "" table.create.properties.light_schema_change: true table.create.properties.replication_num: 1pipeline: name: Sync MySQL Database to Doris parallelism: 1``2023-12-13 22:47:11java.lang.IllegalStateException: Failed to send request to coordinator: com.ververica.cdc.runtime.operators.schema.event.SchemaChangeRequest@9b5c3d87Caused by: java.util.concurrent.ExecutionException: java.util.concurrent.TimeoutException: Invocation of [RemoteRpcInvocation(JobMasterOperatorEventGateway.sendRequestToCoordinator(OperatorID, SerializedValue))] at recipient [akka.tcp://flink@localhost:6123/user/rpc/jobmanager_3] timed out. This is usually caused by: 1) Akka failed sending the message silently, due to problems like oversized payload or serialization failures. In that case, you should find detailed error information in the logs. 2) The recipient needs more time for responding, due to problems like slow machines or network jitters. In that case, you can try to increase akka.ask.timeout. at java.base/java.util.concurrent.CompletableFuture.reportGet(CompletableFuture.java:395) at java.base/java.util.concurrent.CompletableFuture.get(CompletableFuture.java:1999) at com.ververica.cdc.runtime.operators.schema.SchemaOperator.sendRequestToCoordinator(SchemaOperator.java:123) ... 26 moreCaused by: java.util.concurrent.TimeoutException: Invocation of [RemoteRpcInvocation(JobMasterOperatorEventGateway.sendRequestToCoordinator(OperatorID, SerializedValue))] at recipient [akka.tcp://flink@localhost:6123/user/rpc/jobmanager_3] timed out. This is usually caused by: 1) Akka failed sending the message silently, due to problems like oversized payload or serialization failures. In that case, you should find detailed error information in the logs. 2) The recipient needs more time for responding, due to problems like slow machines or network jitters. In that case, you can try to increase akka.ask.timeout. at com.sun.proxy.$Proxy25.sendRequestToCoordinator(Unknown Source) at org.apache.flink.runtime.taskexecutor.rpc.RpcTaskOperatorEventGateway.sendRequestToCoordinator(RpcTaskOperatorEventGateway.java:73) at com.ververica.cdc.runtime.operators.schema.SchemaOperator.sendRequestToCoordinator(SchemaOperator.java:121) ... 26 moreCaused by: akka.pattern.AskTimeoutException: Ask timed out on [Actor[akka.tcp://flink@localhost:6123/user/rpc/jobmanager_3#1975425594]] after [10000 ms]. Message of type [org.apache.flink.runtime.rpc.messages.RemoteFencedMessage]. A typical reason forAskTimeoutException` is that the recipient actor didn't send a reply.


参考回答:

从你提供的错误信息来看,问题可能是由于Flink CDC在向JobManager发送请求时超时导致的。以下是一些可能的解决方法:

  1. 网络问题:检查本地网络连接是否正常,确保Flink和MySQL之间的通信没有被阻塞。
  2. Akka ask timeout:根据错误信息,你可以尝试增加Akka的ask timeout值。在Flink的flink-conf.yaml配置文件中添加或修改以下配置:
akka.ask.timeout: 30 s
  1. 这将把默认的10秒超时时间增加到30秒。你可以根据实际情况调整这个值。
  2. Flink版本兼容性:确认你使用的Flink版本(1.17.2)与Flink CDC 3.0是否兼容。如果存在兼容性问题,尝试使用与Flink CDC 3.0兼容的Flink版本。
  3. 检查Flink和MySQL的配置:确保你在Flink CDC配置中提供的MySQL主机名、端口、用户名和密码是正确的,并且MySQL服务器允许来自Flink CDC的连接。
  4. 查看Flink和MySQL的日志:查看Flink和MySQL的日志,查找可能的错误或警告信息,这些信息可能会帮助你找到问题的原因。
  5. 确认Doris配置:确保你在Flink CDC配置中提供的Doris Fenodes地址、用户名和密码是正确的,并且Doris服务器允许来自Flink CDC的连接。
  6. 更新或重新安装Flink CDC:如果你已经确认了所有的配置都是正确的,但问题仍然存在,你可能需要更新或重新安装Flink CDC,以确保你正在使用的是最新版本并且没有安装错误。


关于本问题的更多回答可点击原文查看:

https://developer.aliyun.com/ask/580693



问题二:Flink CDC中mysqlbinlog保存期限是0,为啥还会报这个找不到binlog的错误呢?


Flink CDC中mysqlbinlog保存期限是0,为啥还会报这个找不到binlog的错误呢?Caused by: java.lang.IllegalStateException: The connector is trying to read binlog starting at Struct{version=1.9.7.Final,connector=mysql,name=mysql_binlog_source,ts_ms=1702519739599,db=,server_id=0,file=mysql-bin.000001,pos=54782888,row=0}, but this is no longer available on the server. Reconfigure the connector to use a snapshot when needed. polardb mysql我是从savepoint恢复任务,本地mysql测试正常


参考回答:

云端数据库并不是永久存储binlog的,你是看官网介绍binlog时间吧,永远存储binlog,要命了,我建议你去看文档,他只是显示给你0,实际是达到25%的存储或者几天就刷到云端了


关于本问题的更多回答可点击原文查看:

https://developer.aliyun.com/ask/580691



问题三:Flink CDC这个异常可能是什么原因导致的吗?


Flink CDC这个异常可能是什么原因导致的吗?

Caused by: java.lang.IllegalStateException: Retrieve schema history failed, the schema records for engine 4e267c1c-99d6-4113-b64e-92367c231e09 has been removed, this might because the debezium engine has been shutdown due to other errors.

场景:flink1.16.0 + flink cdc 2.3.0 抽取Oracle11g的时候,产生的异常?


参考回答:

这个异常 "Retrieve schema history failed, the schema records for engine ... has been removed, this might because the debezium engine has been shutdown due to other errors" 可能是由以下原因导致的:

  • Debezium 引擎意外关闭或者重启,导致 schema 历史记录丢失。
  • Flink CDC 连接器在处理 Oracle CDC 数据时遇到了未知错误或者异常,导致Debezium 引擎被关闭。
  • 系统资源不足或者网络问题,导致 Flink CDC 或者 Debezium 引擎无法正常运行。

为了解决这个问题,你可以尝试以下方法:

  • 检查 Flink CDC 和 Debezium 的日志和错误信息,查找可能的错误根源和解决方案。
  • 确保你的系统资源(如 CPU、内存和磁盘空间)充足,并且网络连接稳定。
  • 考虑更新到最新的 Flink CDC 和 Debezium 版本,以获取最新的 bug 修复和性能优化。


关于本问题的更多回答可点击原文查看:

https://developer.aliyun.com/ask/580688



问题四:为什么Flink CDC默认分配的server-id会重复?


在使用Flink CDC读取MySQL数据时,如果没有手动指定server-id,会报告有相同的server-id错误。一般来说,手动指定server-id可以规避这种情况。但是,手动指定server-id时如何确保与MySQL主从同步使用的不重复?又如何知道哪些server-id尚未使用?另外,为什么Flink CDC默认分配的server-id会重复?


参考回答:

手动指定吧, flink cdc 默认分配的是5400-6400区间,不指定会重复的,而且string 的范围都可以


关于本问题的更多回答可点击原文查看:

https://developer.aliyun.com/ask/580678



问题五:flinkcdc mongodb 报错?


flinkcdc mongodb 报错? 0 [flink-akka.actor.default-dispatcher-7] ERROR org.apache.flink.runtime.source.coordinator.SourceCoordinator - Failed to create Source Enumerator for source Source: MongoDBIncrementalSource

java.lang.NoSuchMethodError: org.apache.avro.Schema$Field.defaultVal()Ljava/lang/Object;


参考回答:

java.lang.NoSuchMethodError 基本是依赖冲突,并且是版本不一致的的那种


关于本问题的更多回答可点击原文查看:

https://developer.aliyun.com/ask/580669

相关实践学习
基于Hologres轻松玩转一站式实时仓库
本场景介绍如何利用阿里云MaxCompute、实时计算Flink和交互式分析服务Hologres开发离线、实时数据融合分析的数据大屏应用。
Linux入门到精通
本套课程是从入门开始的Linux学习课程,适合初学者阅读。由浅入深案例丰富,通俗易懂。主要涉及基础的系统操作以及工作中常用的各种服务软件的应用、部署和优化。即使是零基础的学员,只要能够坚持把所有章节都学完,也一定会受益匪浅。
相关文章
|
2月前
|
运维 数据处理 数据安全/隐私保护
阿里云实时计算Flink版测评报告
该测评报告详细介绍了阿里云实时计算Flink版在用户行为分析与标签画像中的应用实践,展示了其毫秒级的数据处理能力和高效的开发流程。报告还全面评测了该服务在稳定性、性能、开发运维及安全性方面的卓越表现,并对比自建Flink集群的优势。最后,报告评估了其成本效益,强调了其灵活扩展性和高投资回报率,适合各类实时数据处理需求。
|
4月前
|
存储 监控 大数据
阿里云实时计算Flink在多行业的应用和实践
本文整理自 Flink Forward Asia 2023 中闭门会的分享。主要分享实时计算在各行业的应用实践,对回归实时计算的重点场景进行介绍以及企业如何使用实时计算技术,并且提供一些在技术架构上的参考建议。
813 7
阿里云实时计算Flink在多行业的应用和实践
|
6天前
|
存储 分布式计算 流计算
实时计算 Flash – 兼容 Flink 的新一代向量化流计算引擎
本文介绍了阿里云开源大数据团队在实时计算领域的最新成果——向量化流计算引擎Flash。文章主要内容包括:Apache Flink 成为业界流计算标准、Flash 核心技术解读、性能测试数据以及在阿里巴巴集团的落地效果。Flash 是一款完全兼容 Apache Flink 的新一代流计算引擎,通过向量化技术和 C++ 实现,大幅提升了性能和成本效益。
542 10
实时计算 Flash – 兼容 Flink 的新一代向量化流计算引擎
|
3月前
|
SQL 消息中间件 Kafka
实时计算 Flink版产品使用问题之如何在EMR-Flink的Flink SOL中针对source表单独设置并行度
实时计算Flink版作为一种强大的流处理和批处理统一的计算框架,广泛应用于各种需要实时数据处理和分析的场景。实时计算Flink版通常结合SQL接口、DataStream API、以及与上下游数据源和存储系统的丰富连接器,提供了一套全面的解决方案,以应对各种实时计算需求。其低延迟、高吞吐、容错性强的特点,使其成为众多企业和组织实时数据处理首选的技术平台。以下是实时计算Flink版的一些典型使用合集。
|
3天前
|
SQL 运维 数据可视化
阿里云实时计算Flink版产品体验测评
阿里云实时计算Flink基于Apache Flink构建,提供一站式实时大数据分析平台,支持端到端亚秒级实时数据分析,适用于实时大屏、实时报表、实时ETL和风控监测等场景,具备高性价比、开发效率、运维管理和企业安全等优势。
|
19天前
|
运维 搜索推荐 数据安全/隐私保护
阿里云实时计算Flink版测评报告
阿里云实时计算Flink版在用户行为分析与标签画像场景中表现出色,通过实时处理电商平台用户行为数据,生成用户兴趣偏好和标签,提升推荐系统效率。该服务具备高稳定性、低延迟、高吞吐量,支持按需计费,显著降低运维成本,提高开发效率。
53 1
|
22天前
|
运维 数据处理 Apache
数据实时计算产品对比测评报告:阿里云实时计算Flink版
数据实时计算产品对比测评报告:阿里云实时计算Flink版
|
2月前
|
存储 运维 监控
阿里云实时计算Flink版的评测
阿里云实时计算Flink版的评测
67 15
|
20天前
|
运维 监控 Serverless
阿里云实时计算Flink版评测报告
阿里云实时计算Flink版是一款全托管的Serverless实时流处理服务,基于Apache Flink构建,提供企业级增值功能。本文从稳定性、性能、开发运维、安全性和成本效益等方面全面评测该产品,展示其在实时数据处理中的卓越表现和高投资回报率。
|
21天前
|
存储 运维 监控
实时计算Flink版在稳定性、性能、开发运维、安全能力等等跟其他引擎及自建Flink集群比较。
实时计算Flink版在稳定性、性能、开发运维和安全能力等方面表现出色。其自研的高性能状态存储引擎GeminiStateBackend显著提升了作业稳定性,状态管理优化使性能提升40%以上。核心性能较开源Flink提升2-3倍,资源利用率提高100%。提供一站式开发管理、自动化运维和丰富的监控告警功能,支持多语言开发和智能调优。安全方面,具备访问控制、高可用保障和全链路容错能力,确保企业级应用的安全与稳定。
31 0

相关产品

  • 实时计算 Flink版
  • 推荐镜像

    更多